6.2.1Construction of the marine evacuation systems
6.2.1.1The passage of the marine evacuation system shall provide for safe descent of persons of various apes, sizes and physical capabilities, wearing approved lifejackets, from the embarkation station to the floating plationn or survival craft.
6.2.1.2Strength and construction of the passage and platiorm shall be to the satisfaction of the Administration.
6.2.1.3The platiorm, if fitted, shall be: 3 such that sulficient buoyancy will be provided for the working load. In the case of an inflatable platiorm, the main buoyancy chambers, which for this purpose shall include any thwarts or floor inflatable structural members, are to meet the require-ments of section 4.2 based upon the plationm capacity, except that the capacity shall be obtained by dividing by 0.25 the usable area piven in paragraph 6.2.1.3.3; 2 stable in a seaway and shall provide a sale working area for the system operators; 3 of suffioent area that will provide for the securing of at least two liferafts for boarding and to accommodate at least the number of persons that af any time are expected to be on the plationm. This usable platiorm area shall be at least equal to: 20% of total number of persons that the marine evacuation system is Certified for on 4. or 10m’, whichever is the greater. However, Administrations may approve alternate arrangements 4A seli-draining; Y 5 subdivided in such a way that the gas from any one compartment will not restrict its operational use as a means of The bucyancy tubes shall be subdivided or protected against damage occurring from contact with the ship's side; “4 fitted with a stabilizing system to the satisfaction of the Administration; 7 restrained by a bowsing line or other positioning systems which are designed to deploy automatically and, W necessary, to be capable of being adjusted to the position required for evacuation; and 8 = provided with moonng and bowsing line patches of sufficent strength to securely attach the largest inflatable literaft associated with the system.
6.2.1.4If the passage gives direct access to the survival craft, it should be provided with a quick-release aranpenent.
6.2.2Performance of the marine evacuation system
6.2.2.1A marine evacuation system shall be- 1s capable of deployment by one person; «2 suchas to enable the total number of persons for which it is designed, to be transferred from the ship inte the inflated literaits within a period of 30 min in the case of a passenger ship and of 10 min in the case of a cargo ship from the time the abandon ship signal is piven; 3) arranged such that liferaits may be securely attached to the platform and released from the platiorm by a person either in the liferatt or on the platiorm; * Refer to the Revised recommendation on testing of life-saving appliances iresolution MSC_Al(70), as amended). 4 capable of being deployed from the ship under unfavourable conditions of trim of up to 10° and list of up to 20° ether way; 4 inthe case of being fitted with an inclined slice, such that the angle of the slide to the horizontal isc Jl pare a range of 30° to 35° when the ship is upnght and in the lightest sea-going condition; 2 im the case of a passenger ship, a maximum of 55° in the final stage of flooding set by the requirements in regulation H-1/8; 6 evaluated for capacity by means of timed evacuation deployments conducted in harbour; J capable of providing a satisfactory means of evacuation in a sea state associated with a wind of jorce 6 on the Beautort scale: 40 designed fo, as far as practicable, remain effective under conditions of icing; and § 0 constructed that only a minimum amount of routine maintenance is necessary. Any part requiring maintenance by the ship's crews shall be readily accessible and easily maintained.
6.2.2.2Where one or more marine evacuation systems are provided on a ship, at least 50% of such systems shall be subjected fo a trial deployment after installation. Subject to these deployments being satisfactory, the untried systems are to be deployed within 12 months of installation.
6.2.3Inflatable liferafts associated with marine evacuation systems Any inflatable liferaft used in conjunction with the mafine evacuation system shall: J conform with the requirements of section 4.2; a be sited close to the system container but be capable of dropping clear of the deployed system and boarding plathorm, o 3 be canal cca Sieg mg ack wl arargements whch wil enable it to be moored alongside the ; 4 be stowed in accordance with regulation HV/13.4; and 5 be provided with pre-connected or easily connected retrieving lines to the platiorm.
6.2.4Containers for marine evacuation systems
6.2.4.1The evacuation passage and platiorm shall be packed in a container that ts: —) oso constructed as to withstand hard wear under conditions encountered at sea; and 2 as faras practicable watertight, except for drain holes in the container bottom.
6.2.4.2The container shall be marked with: “lo maker's name or trademark; 2 = serial number; 3 name of approval authority and the capacity of the system; A SOLAS; 5 date of manufacture (month and year); 6 = date and place of last service; 7 maamum permitted height of stowage above waterline; and 4 stowage position on board.
6.2.4.3Launching and operating instructions shall be marked on or in the vicinity of the container.
6.2.5Marking on marine evacuation systems The marine evacuation system shall be marked with: 3 maker's name or trademark; 2 serial number; 3 date of manulacture (month and year); 4 name of approving authority; 5 name and place of servicing station where it was last serviced, along with the date of servicing: and 4 the capacity of the system. Other life-saving appliances