ข้อบังคับที่ 11
Survival craft muster and embarkation arrangements
ภาค Bหมวด I8 ย่อหน้า
1Lifeboats and liferafts for which approved launching appliances are required shall be stowed as close to accommodation and service spaces as possible.
2Muster stations shall be provided close to the embarkation stations. Each muster station shall have sufficient clear deck space to accommodate all persons assigned to muster at that station, but at least 0.35 m2 per person.
3Muster and embarkation stations shall be readily accessible from accommodation and work areas. • Refer to Symbols related to life-saving appliances and arrangements (resolution A.760(18), as amended) and/or tables 1 and 2 of Escape route signs and equipment location markings (resolution A.1116(30)), as appropriate. Refer to the new symbols in tables 1 and 2 of resolution A.1116(30) where the symbols for a specific item are differently expressed in resolutions A.760(18), as amended, and A.1116(30).
4Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation 11-1/42 or 11-1/43, as appropriate.
5Alleyways, stairways and exits giving access to the muster and embarkation stations shall be lighted. Such lighting shall be capable of being supplied by the emergency source of electrical power required by regulation 11-1/42 or 11-1/43, as appropriate. In addition to and as part of the markings required under regulation 11-2/13.3.2.5.1, routes to muster stations shall be indicated with the muster station symbol, intended for that purpose, in accordance with the recommendations of the Organization.*
6Davit-launched and free-fall launched survival craft muster and embarkation stations shall be so arranged as to enable stretcher cases to be placed in survival craft.
7An embarkation ladder complying with the requirements of paragraph 6.1.6 of the Code extending, in a single length, from the deck to the waterline in the lightest seagoing condition under all conditions of trim of up to 10° and a list of up to 20° either way shall be provided at each embarkation station or at every two adjacent embarkation stations for survival craft launched down the side of the ship. However, the Administration may permit such ladders to be replaced by approved devices to afford access to the survival craft when waterborne, provided that there shall be at least one embarkation ladder on each side of the ship. Other means of embarkation enabling descent to the water in a controlled manner may be permitted for the liferafts required by regulation 31.1.4.
8Where necessary, means shall be provided for bringing the davit-launched survival craft against the ship's side and holding them alongside so that persons can be safely embarked.