ข้อบังคับที่ 32
Personal life-saving appliances
Unified Interpretation 6
ภาค Bหมวด III17 ย่อหน้า
1Lifebuoys
1.1Cargo ships shall carry not less than the number of lifebuoys complying with the requirements of regulation 7.1 and section 2.1 of the Code prescribed in the following table: Length of ship in metres Minimum number of lifebuoys Under 100
8100 and under 150
10150 and under 200
12200 and over
1.2Self-igniting lights for lifebuoys on tankers required by regulation 7.1.3 shall be of an electric battery type.
2Lifejacket lights
2.1This paragraph applies to all cargo ships.
2.2On cargo ships, each lifejacket shall be fitted with a lifejacket light complying with the requirements of paragraph 2.2.3 of the Code.
2.3Lights fitted on lifejackets on board cargo ships prior to 1 July 1998 and not complying fully with paragraph 2.2.3 of the Code may be accepted by the Administration until the lifejacket light would normally be replaced or until the first periodical survey after 1 July 2001, whichever is the earliest.
3Immersion suits
3.1This paragraph applies to all cargo ships. However, with respect to cargo ships constructed before
1July 2006, paragraphs 3.2 to 3.5 shall be complied with not later than the first safety equipment survey on or after 1 July 2006.
3.2An immersion suit of an appropriate size complying with the requirements of section 2.3 of the Code shall be provided for every person on board the ship. However, for ships other than bulk carriers, as defined in regulation IX/1, these immersion suits need not be required if the ship is constantly engaged on voyages in warm climates* where, in the opinion of the Administration, immersion suits are unnecessary.
3.3If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed, including remotely located survival craft carried in accordance with regulation 31.1 .4, additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch or working at those locations at any time.
3.4Immersion suits shall be so placed as to be readily accessible and their position shall be plainly indicated.
3.5The immersion suits required by this regulation may be used to comply with the requirements of regulation 7.3.