Section 2.5
Thermal protective aids
Chapter IIPage 132 clauses
This content comes from OCR text extraction
The text may contain inaccuracies, especially units and clause numbers. Treat the original scanned pages or the official IMO document as authoritative.
2.5.1A thermal protective aid shall be mide of waterproof material having a thermal conductance of not more than 7,800 Wim? - K) and shall be so constructed that, when used to enclose a person, it shall reduce both the convective and evaporative heat loss from the wearer's body.
2.5.2The thermal protective aid shall: 1A cover the whole body of persons of all sizes wearing a lifejacket with the exception of the face. Hands shall also be covered unless permanently attached gloves are provided: 2 be capable of being unpacked and easily donned without assistance in a survival craft of rescue boat; and 3 permit the wearer to remove it in the water in not more than 2 min, if it impairs ability to swim. 2.5.3) The thermal protective aid shail function properly throughout an air temperature range —30°C to 420°C. Visual signals