4.1.1Construction of liferafts
4.1.1.1Every liferaft shall be so constructed as to be capable of withstanding exposure for 30 days afloat in all sea conditions.
4.1.1.2The liferait shall be so constructed that when it is dropped into the water from a height of 18 m, the literait and its equipment will operate satistactorily. If the lileraft is to be stowed at a height of more than 18 m above the waterline in the lightest seagoing condition, it shall be of a type which has been satistactorily drop-tested from at least that height.
4.1.1.3The floating liierait shall be capable of withstanding repeated jumps onto it from a herght of at least